  1. List of Items 


#

Item Code

Item Description

Grand Total

BID Fee

1

12971

CAP; ENTRANCE; SIZE 2 IN

9

100

2

20042

BASE, ELECTRICAL; EXTENDED; SIZE 24 IN; HOT DIP GALVANIZED; FOR 69KV POLYMER POST INSULATOR

1,311

2,000

3

20784

SWITCH, DISCONNECT; 15KV; 1200A, 110KV BIL ROYAL SWITCHGEAR

38

1,000

4

20785

SWITCH, DISCONNECT; 15KV; 2000A, 110KV BIL ROYAL SWITCHGEAR

6

1,000

5

22284

SEL-787, 48Vdc

1

500

6

23528

BREAKER, CIRCUIT; PN: EA32; 220V; 5A; 2.5KA INTRPTNG; 2 PL; MFR: FUJI

6

10

7

24059

OIL; TRANSFORMER; MFR: NYNAS

80

2,000

8

52284

RAIL, DIN; FOR ALL TYPES OF BREAKERS

24

50

9

52432

RAIL, DIN; OPEN

20

50

10

55256

ARRESTER; SURGE STATION-TYPE; POLYMER; 60KV; 48KV-MCOV

20

100

11

55406

BREAKER, CIRCUIT MINIATURE; 10A; 2 PL; MFR: SIEMENS

34

50

12

61658

BREAKER, CIRCUIT MINIATURE; 220V; 60A; 2 PL

1

50

13

61990

BREAKER, CIRCUIT; POWER DEAD TANK AIR INSULATED OUTDOOR; VACUUM; 15KV, 110KV BIL; 1200A; 3 PH

4

1,000

14

62112

SWITCH, DISCONNECT; HOOKSTICK OPERATED; 15KV; 2000A

3

400

15

62260

SWITCH, DISCONNECT; DOUBLE SIDE BREAK; 69KV; 2000A; MANUAL-OPERATED VERTICAL-CONFIGURATION

6

1,000

16

62261

SWITCH, DISCONNECT; MOTOR-OPERATED, DOUBLE SIDE BREAK; 69KV; 2000A; VERTICAL-CONFIGURATION

3

2,000

17

62272

RELAY; TRANSFORMER CURRENT DIFFRENTIAL; PN: 787,07871 X 1ACACAA5850331; SIZE 5.67 IN X 7.56 IN X 5.8 IN; 125VDC; 0.3A; 50-60HZ; -40 TO 185DEG F; MFR: SEL

7

2,700

18

62324

BASE, ELECTRICAL; INSULATING; FOR ARRESTER 120KV

5

300

19

62360

BLOCK, TERMINAL; 20A; DIN RAIL MNT

99

50

20

62373

CHARGER, BATTERY; 240VAC/125VDC; 50A; 1 PHASE

4,000

2,000

21

62375

ENCLOSURE; RACK NETSHELTER; PN: AR3100; SIZE 1991MM H; 1070MM DPT; 600MM, 19 IN RACK W; NOT RACK MNT; MFR: APC; NUMBER OF RACK UNIT: 4U, COLOR: BLACK

3

300

22

62378

CLAMP; POTENTIAL-EQUALIZATION; 350V, 100KA

3

30

23

62413

CONVERTER; IP-TO-SERIAL RS-232/422/485

2

100

24

62528

CONVERTER; DIRECT CURRENT; VPRI 48VDC/24VDC; 5A

8

100

25

62691

BLOCK, TERMINAL; 40A; DIN RAIL MNT

2

100

26

62922

CLAMP; END; FOR TERMINAL BLOCK DIN-RAIL-TYPE

3,000

50

27

63304

PLATE; PARTITION; PN: TPNS-UK-0706647; SIZE 2MM W X 80MM L; GRAY; ROHS; -60 TO 105DEG C; MFR: CAT

3

100

28

63305

MARKER, STRIP; SIZE 16MM; WHITE

1,500

50

29

63621

ENCLOSURE; SWITCHGEAR; RMU 5-BAY

1,500

400

30

63634

TESTBLOCK; FTL; PN: 20016AA; 20 PL; MFR: SECUCONTROL

1,000

1,000

31

63638

BLOCK, TERMINAL; 50A; DIN RAIL MNT

1

500

32

63848

TESTBLOCK; FTL; PN: 20022AA; 20 PL; MFR: SECUCONTROL

18

50

33

63918

CHARGER, BATTERY; 240VAC, 125VDC; 30A; 1 PHASE

4,000

500

34

63993

CLAMP; DEADEND LOOP; SIZE 2/0; 3/8 IN DIA; 34.5KV; MFR: OHDL

1

10

35

64105

SWITCH, DISCONNECT; 38KV; 600A

2

500

36

64130

CONTROLLER, AUTOMATION; PROGRAMMABLE; PN: SEL-2411,241121A3A3A5 X 5 X 0641; 125VDC; MFR: SEL; EQUIPMENT-MONITORING

100

100

37

64155

MOTOR, DC; PN: SPS-2; 125VDC; CHARGING; MFR: SIEMENS

221

100

38

64157

COIL; CLOSED; 125VDC; MFR: SIEMENS; 3AH5

1

10

39

64160

COIL; CLOSED; 125VDC; 3.5A; MFR: ALSTOM

1

10

40

64161

MOTOR, DC; 1.6KW; 125VDC; CHARGING; MFR: ALSTOM

1

50

41

64211

TESTBLOCK; PN: 20006AA FTL; 20 PL; MFR: SECUCONTROL

1

140

42

64685

CONVERTER; DIRECT CURRENT; VPRI 125VDC/24VDC; 20A

1

18

43

65078

CABLE, USB; SERIAL; PN: SEL-C662,C662-15; SIZE 15FT; MFR: SEL

2

10

44

65295

SWITCH, NETWORK; ETHERNET MANAGED 24 PORT; PN: 2730M,2730M0ARCC2222AAAAX 1; CONN RJ45 FEMALE; 24-250VDC OPERATIONAL; 2A CONTINUOUS CARRY; -40-85DEG C (-40-185DEG F) OPERATING; MFR: SEL

3

200

45

65607

BUSBAR; SIZE 2 IN W X 12 IN L; BAR BUS COPPER

1

50

46

65615

SWITCH, VACUUM; 15.5KV, 125KV BIL; 200A; 1 PHASE

1

500

47

66031

SWITCH, DISCONNECT; 15KV; 3000A; MFR: ROYAL-SWITCHGEAR

1

450

48

66168

TESTBLOCK; FTL; PN: 20037AA; 20 PL; MFR: SECUCONTROL

14

50

49

66604

CABLE; DISPLAY PORT; CONN MALE TO MALE

3

20

50

66911

CHARGER, BATTERY; 48VDC; 50A; 24-CELL

1

500

51

77933

CLAMP; BUS; SIZE 4/0-795MCM; 3 IN BOLT CIRCLE DIA; SINGLE CONDUCTOR

2

200

52

126475

CHARGER, BATTERY; SINGLE PHASE; 220VAC INPUT, 48VDC; 30A; 60HZ

2

300

53

165889

BREAKER, CIRCUIT; MINIATURE; 240V; 80A; 2 PL; DIN RAIL MNT

75

10

54

166111

SENSOR, TEMPERATURE; AND HUMIDITY; PN: 2TH ETH; MFR: PAPAGO

1

50

55

201160

SWITCH, DISCONNECT; 23KV; 1200A; PORCELAIN

6

500

56

205437

RELAY; OVERCURRENT; PN: 751102CCCCC7C850871; 48VDC; 60 HZ; MFR: SEL

1

500

57

205546

RELAY; ARC FLASH PROTECTION; PN: VAMP 321; 48VDC; MFR: SCHNEIDER ELECTRIC

18

500

58

221831

SWITCH, DISCONNECT; HOOKSTICK OPERATED; 15.5KV; 600A; 60HZ; 1 PL; 3 IN BC MNT; PORCELAIN INSULATOR; IEEE STD. C37.30.1; 25KA MOMENTARY RATING; SINGLE-THROW, STATION CLASS

3

500

59

221938

TESTBLOCK; PN: FTLP08005AA; 600V; 30A; 8 PL; MFR: SECUCONTROL; 4-CURRENT, 4-SIGNAL POLES

2

100

60

221939

TESTBLOCK; 600V; 30A; 20 PL; MFR: SECUCONTROL; 16-CURRENT, 4-SIGNAL POLES

18

100

                     Note: Bid Fee Is Non-Refundable 


  1. Eligibility Requirements - All interested Bidders must meet the following eligibility criteria in order to proceed to the Technical Evaluation stage:


a. For Accredited Supplier 

  1. Sworn statement from the Bidder affirming that they are not blacklisted, barred, or sanctioned by any Aboitiz Business Unit.

  2. Supplier Portal Profile or Supplier ID 


b. For Accredited Supplier 

  1. Sworn statement from the Bidder affirming that they are not blacklisted, barred, or sanctioned by any Aboitiz Business Unit.

  2. Proof of application for vendor accreditation in our online Supplier Portal. Kindly request the vendor accreditation details from the Bid Administrator.


For new items that have not yet been accredited by the AboitizPower Distribution Utilities, the Bidder must first undergo the brand accreditation process. The list of accredited brands is available in the bid documents. Furthermore, Bidders who have applied for Vendor Accreditation must be successfully accredited prior to the awarding of the contract.

 

Interested bidders may submit their Letter of intent and Eligibility Requirements and obtain further information from the Bid Administrator, Ms Ruth R Chiong via email to ruth.chiong@visayanelectric.com on or before October 17, 2025 @5PM.



3. Timeline of Activities 


ACTIVITIES

SCHEDULE

1. Submission of the Letter of Intent and Eligibility Documents

October 10 -17, 2025 @ 5:00 PM 

2. Issuance of Bidding Documents 

October 20, 2025 


An online Pre-Bid Conference will be conducted via Google Meet to discuss the details of the project and to address any questions or clarifications regarding the Bid Documents. The meeting schedule and access details will be provided together with the Bid Documents. 


The Bids and Award Committee reserves the right to accept or reject any bid, to annul the bidding process, and to reject all bids that at any time prior to contract award, without hereby incurring any liability to the affected bidder or bidders. 




Very truly yours,



Bids and Awards Committee

Aboitiz Power - Distribution Utilities

Aboitiz Power Corporation,

Gov. Manuel A. Cuenco Ave., Kasambagan, 

Cebu City, Philippines



SGD. Clovis B. Racho

Chairperson, Bids and Awards Committee


 
 
bottom of page